Photovoltaic Systems and Fire Safety: What’s Changing with the New 2025 Guidelines

26/10/2026

This article is based on the “Caffè Tecnico” sessions, M&E’s monthly meetings where professionals share regulatory updates, practical case studies and technical insights to continuously strengthen the team’s expertise.

The installation of photovoltaic systems continues to increase, bringing greater attention to fire safety requirements. To harmonise design criteria, new guidelines for the design and installation of photovoltaic systems were issued through DCPSTAE Circular No. 14030 of 1 September 2025. The document introduces updated technical provisions for photovoltaic installations serving activities subject to fire prevention controls. The requirements apply to photovoltaic systems installed in facilities subject to Italian Presidential Decree No. 151/2011, including industrial, commercial and logistics buildings.
Ground-mounted installations, plug-and-play systems and installations with a capacity below 800 W are among those excluded. For projects initiated before 1 September 2025, the previous regulations may still be applied, provided the conditions established under the transitional provisions are met.

When Photovoltaic Installations Affect Fire Safety

Installing a photovoltaic system generally constitutes a significant modification to an existing facility, as it may affect its fire safety conditions. It is therefore necessary to assess whether the intervention increases the fire risk and, where applicable, initiate the procedures required under Presidential Decree No. 151/2011. When a project complies with the guidelines and the risk assessment identifies no additional critical issues, the installation does not normally result in an increase in fire safety risk.

Main Changes to Design Requirements

The new guidelines distinguish between BAPV (Building-Applied Photovoltaics), installed on the building envelope, and BIPV (Building-Integrated Photovoltaics), incorporated directly into the roof or façade. This classification determines the technical assessments and safety measures required. Key provisions include the correct positioning of inverters and converters, compliance with safety distances from openings, smoke vents and other rooftop installations, the subdivision of large photovoltaic arrays into accessible sections, and the use of non-combustible or appropriately fire-resistant materials where required. Particular attention is given to emergency isolation devices, which must be easily accessible to emergency responders, and to any associated energy storage systems, which require a specific fire risk assessment.

The guidelines also emphasise the importance of periodic maintenance, which must be documented in accordance with fire safety regulations. In addition to routine inspections, it is necessary to monitor the condition of photovoltaic modules, record any detected faults, document component replacements and carry out all activities required to maintain the system’s fire safety conditions over time.

Integrated Design from the Earliest Stages

The new guidelines confirm that a photovoltaic system cannot be designed independently of the building on which it is installed. Architectural design, electrical engineering, fire safety and energy efficiency must be developed in a coordinated manner to ensure regulatory compliance, safety and performance.

This is the approach adopted by M&E: integrating different areas of expertise from the earliest project stages, turning regulatory obligations into opportunities to create safer, more efficient and more sustainable buildings.

Other articles

In a world where buildings and construction account for a substantial portion of global greenhouse-gas emissions, sustainable design is no longer optional, it is essential.
Designing technologies for a better world and a better future: this is the philosophy that M&E Srl, an engineering firm, has applied for twenty-five years in the design of mechanical, electrical, specialist, and fire-protection systems. Our expertise has been built through the delivery of complex projects—from hospitals to shopping centres, from museums to industrial facilities, and even wineries, a sector in which we have developed highly specialized experience.

Air Conditioning
Plumbing & Sanitary
Electrical & Specialty
Mechanical Ventilation
Building Management Systems (BMS)
Renewable Energy
BIM Design

PROJECT MANAGEMENT
CONSTRUCTION MANAGEMENT
QUANTITY SURVEY
WORKS SUPERVISION AUTHORITY
COMMISSIONING AUTHORITY

Energy Modeling
Building Physics
THERMAL COMFORT
Energy Audits
Decarbonization plans
ENERGY EFFICIENCY AND MANAGEMENT
Energy Performance Certificates (EPC)
Feasibility Studies
Lighting
Safety
Fire Safety
Acoustics
Microclimatic Analyses
Vertical Transportation Analysis
Life Cycle Assessment (LCA) and Life Cycle Costing (LCC)

BREEAM CERTIFICATION
LEED CERTIFICATION
WELL CERTIFICATION
WIRESCORE CERTIFICATION
DNSH and European Taxonomy

Florence Headquarter
Via Giovanni da Cascia, 15 – 50127 Firenze
postmaster@meesrl.com
Tel: +39 055 334071
Tel: +39 055 364841

M&E Srl is a dynamic, young, and continually growing organization, always seeking new professionals to join our team. Would you like to be part of our group? Send us your résumé: we offer exciting opportunities with a professional, growth-oriented approach.

  • MECHANICAL DESIGNER ENGINEER
  • ELECTRICAL DESIGN ENGINEER
  • CAD DRAFTSPERSON
  • SENIOR FIRE PREVENTION DESIGNER
In-depth insights, news, and updates from the world of engineering. Read the articles on our blog.

M&E Srl is a dynamic, young, and continually growing organization, always seeking new professionals to join our team. Would you like to be part of our group? Send us your résumé: we offer exciting opportunities with a professional, growth-oriented approach.

  • MECHANICAL DESIGNER ENGINEER
  • ELECTRICAL DESIGN ENGINEER
  • CAD DRAFTSPERSON
  • ADMINISTRATIVE/SECRETARIAL APPRENTICE
  • ENIOR ADMINISTRATIVE/SECRETARIAL CLERK

SEARCH